An exception error 0xc000001d occurs when running a backup resulting in an AIP Exit Code 701

Summary

When executing a backup, the following error occurs.

11/23/2018 09:00:07.764 Init returns 0x32
:
11/23/2018 09:00:28.455 exception(0xc000001d) caught,starting block 0, nbr of blocks:32, status: 3 Level=ERROR [0]
11/23/2018 09:00:28.456 ##### Pipe line encounter ERROR: 9999, last error code:0, 0 Level=ERROR [0]
11/23/2018 09:00:28.458 ###### something wrong during run pipe line
:
11/23/2018 09:00:49.852 {IDS_STRING3018}Exit Code: -701

Cause

This error is because the code used in AIP2016 is not compatible with CPUs Xeon Gold/Silver/Bronze.

Resolution

This issue had been fixed in AIP2018. Ab upgrade to AIP2018 is recommended.

Target Product

– ActiveImage Protector 2016



?akb&p=2121

Table of Contents